L4006; L6006 Aquastat® Controller

foto producto

Description:

Aquastat® Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required.




  • Totally enclosed Micro Switch snap-acting switches operate on temperature rise to setpoint.
  • Visible control point scale and external adjustment screw permiteasy setting.
  • Horizontal or vertical insertion of the sensing element.
  • Direct or well immersion of the sensing element.
  • Models available for strap-on mounting.
  • Remote bulb model may be used to sense air temperature in ductsand in outside air sensing applications.
  • TRADELINE models include heat-conductive compound.
  • Select models have wells.

Dimensions & Specifications:

Case Dimensions: 5 5/8 in. high x 2 in. wide x 2 1/8 in. deep (143 mm high x 51 mm wide x 54 mm deep)
Bulb Size: 3/8 in. x 2 7/8 in. copper (10 mm x 73 mm copper)
Maximum Ambient Temperature: 150 F (66 C)
Operating Temperature Range: 100 F to 240 F (38 C to 116 C)

Electrical Ratings
(Full Load) (Locked Rotor) (Millivolt)
L4006A,B 8A @ 120 Vac
5.1A @ 240 Vac
48A @ 120 Vac
30.6A @ 240 Vac
0.25 A @ 0.25 to
12 Vdc
L4006E 8A @ 120 Vac
1.3A @ 240 Vac
48A @ 120 Vac
30.6A @ 240 Vac
0.25 A @ 0.25 to
12 Vdc
L6006 8A @ 120 Vac
5.1A @ 240 Vac
48A @ 120 Vac
30.6A @ 240 Vac
0.25 A @ 0.25 to
12 Vdc
curvas

Product Number Application Operating Temperature
Range
Differential Temperature Switching Action Mounting Insulation Depth Spud Size Includes
(F) (C) (F) (C) (inch) (mm) (inch)
L4006A1009 High or Low limit 100 F to 240 F 38 C to 116 C 5 F Fixed 3 C fixed SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 1 1/2 in. 38 mm 3/4 in. NPT 1 1/2 in. (38 mm) insulation
L4006A1017 High or Low limit 100 F to 240 F 38 C to 116 C 5 F to 30 F adj. 3 C to 17 C adj. SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 1 1/2 in. 38 mm 3/4 in. NPT 1 1/2 in. (38 mm) insulation
L4006A1132 High or Low limit 100 F to 240 F 38 C to 116 C 5 F Fixed 3 C fixed SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm 3/4 in. NPT 3 in. (76 mm) insulation, stop factory-set at 160 F (71 C).
* L4006A1678 High or Low limit 100 F to 240 F 38 C to 116 C 5 F to 30 F adj. 3 C to 17 C adj. SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm 3/4 in. NPT 3 in. (76 mm) insulation, stop factory-set at 240 F (116 C), and heatconductive compound.
* L4006A1959 High or Low limit 40 F to 180 F 4 C to 82 C 2 F fixed 1 C fixed SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm 3/4 in. 1 1/2 in. (38 mm) insulation and heatconductive compound.
* L4006A1967 High or Low limit 100 F to 240 F 38 C to 116 C 5 F to 30 F adj. 3 C to 17 C adj. SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 1 1/2 in. 38 mm 3/4 in. 1 1/2 in. (38 mm) insulation, stop factory-set at 240 F (116 C).
L4006A2007 High or Low limit 100 F to 240 F 38 C to 116 C 5 F to 30 F adj. 3 C to 17 C adj. SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm 3/4 in. 3 in. (76 mm) insulation.
L4006A2148 High or Low limit 100 F to 200 F 38 C to 93 C 5 F to 30 F adj. 3 C to 17 C adj. SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm 3/4 in. _
L4006B1007 Circulator 100 F to 240 F 38 C to 116 C 5 F Fixed 3 C fixed SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 1 1/2 in. 38 mm 1/2 in. 1 1/2 in. (38 mm) insulation
* L4006B1155 Circulator 100 F to 240 F 38 C to 116 C 5 F to 30 F adj. 3 C to 17 C adj. SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm _ 3 in. (76 mm) insulation, stop factory-set at 240 F (116 C), and heatconductive compound.
L4006B1163 Circulator 100 F to 240 F 38 C to 116 C 5 F to 30 F adj. 3 C to 17 C adj. SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm _ 3 in. (76 mm) insulation.
* L4006E1067 High Limit; Manual Reset 130 F to 270 F 54 C to 132 C Manual Reset Manual Reset SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm _ 3 in. (76 mm) insulation, stop factory-set at 250 F (121 C); well adapter and heatconductive compound.
L4006E1091 High Limit; Manual Reset 130 F to 270 F 54 C to 132 C Manual Reset Manual Reset SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm _ 3 in. (76 mm) insulation.
L4006E1125 High Limit; Manual Reset 100 F to 200 F 18 C to 93 C Manual Reset Manual Reset SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 3 in. 76 mm _ _
* L4006H1004 High Limit; strap-on mounting on well mount. 100 F to 240 F 38 C to 116 C Manual Reset Manual Reset SPST, contacts break on temperature rise. Horizontal or Vertical Mounting 1 1/2 in. 38 mm _ Bracket for strap-on mounting, stop factory-set at 240 F (116 C), and heatconductive compound.
L6006A1004 Circulator Control and High Limit or Low Limit 100 F to 240 F 38 C to 116 C 5 F 3 C SPDT Horizontal or Vertical Mounting _ _ 1/2 in. _
L6006A1012 Circulator Control and High Limit or Low Limit 100 F to 240 F 38 C to 116 C 5 F to 30 F adj. 3 C to 17 C adj. SPDT Horizontal or Vertical Mounting _ _ 1/2 in. _
# L6006A1145 Circulator Control and High Limit or Low Limit 100 F to 240 F 38 C to 116 C 5 F to 30 F adj. 3 C to 17 C adj. SPDT Horizontal 3 in. 76 mm _ Stop factory-set at 240F (116 C) and heat-conductive compound
L6006A1244 Circulator Control and High Limit or Low Limit 100 F to 240 F 38 C to 116 C 5 F to 30 F adj. 3 C to 17 C adj. SPDT Horizontal or Vertical Mounting 3 in. 76 mm _ _
* L6006C1018 Circulator Control and High Limit or Low Limit 65 F to 200 F 18 C to 93 C 5 F to 30 F adj. 3 C to 17 C adj. SPDT Horizontal or Vertical or Strap-onmounting _ _ _ _

* TRADELINE models
# SUPER TRADELINE models